FLIR A3xx

Wärmebildkamera FLIR A3xx

FLIR A3xx weiterführende Links

FLIR A3xx Eigenschaften

Part No.Product nameImaging and optical data: IR resolutionImaging and optical data: Thermal sensitivity/NETDImaging and optical data: Field of view (FOV)Imaging and optical data: Minimum focus distanceImaging and optical data: Focal lengthImaging and optical data: Spatial resolution (IFOV)Imaging and optical data: Lens identificationImaging and optical data: F-numberImaging and optical data: Image frequencyImaging and optical data: FocusImaging and optical data: ZoomDetector data: Detector typeDetector data: Spectral rangeDetector data: Detector pitchDetector data: Detector time constantMeasurement: Object temperature rangeMeasurement: AccuracyMeasurement analysis: SpotmeterMeasurement analysis: AreaMeasurement analysis: IsothermMeasurement analysis: Measurement optionMeasurement analysis: Difference temperatureMeasurement analysis: Reference temperatureMeasurement analysis: Atmospheric transmission correctionMeasurement analysis: Optics transmission correctionMeasurement analysis: Emissivity correctionMeasurement analysis: Reflected apparent temperature correctionMeasurement analysis: External optics/windows correctionMeasurement analysis: Measurement correctionsAlarm: Alarm functionsAlarm: Alarm outputAlarm: ScreeningSet-up: Color palettesSet-up: Set-up commandsStorage of images: Storage mediaStorage of images: File formatsEthernet: EthernetEthernet: Ethernet, typeEthernet: Ethernet, standardEthernet: Ethernet, connector typeEthernet: Ethernet, communicationEthernet: Ethernet, video streamingEthernet: Ethernet, image streamingEthernet: Ethernet, powerEthernet: Ethernet, protocolsDigital input/output: Digital input, purposeDigital input/output: Digital inputDigital input/output: Digital output, purposeDigital input/output: Digital outputDigital input/output: Digital I/O, isolation voltageDigital input/output: Digital I/O, supply voltageDigital input/output: Digital I/O, connector typeComposite video: Video outComposite video: Video, standardComposite video: Video, connector typePower system: External power operationPower system: External power, connector typePower system: VoltageEnvironmental data: Operating temperature rangeEnvironmental data: Storage temperature rangeEnvironmental data: Humidity (operating and storage)Environmental data: EMCEnvironmental data: EncapsulationEnvironmental data: ShockEnvironmental data: VibrationPhysical data: WeightPhysical data: Camera size (L × W × H)Physical data: Tripod mountingPhysical data: Base mountingPhysical data: Housing materialShipping information: Packaging, typeShipping information: List of contentsShipping information: Packaging, weightShipping information: Packaging, sizeShipping information: EAN-13Shipping information: UPC-12Shipping information: Country of origin 
48201-1001FLIR A300320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.330 HzAutomatic or manual (built in motor)1–8× continuous, digital, interpolating zooming on imagesFocal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of reading---------------Color palettes (BW, BW inv, Iron, Rain)Date/time, Temperature (°C/°F)Built-in memory for image storageStandard JPEG, 16-bit measurement data includedControl and image100 MbpsIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietaryMPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L516-bit 320 × 240 pixels @ 3 Hz
- Radiometric
Power over Ethernet, PoE IEEE 802.3af class 0. In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet, in some rare cases the camera will not be powered. In such cases, power the camera using the external power cable, or modify the camera according to Service bulletin SB14-006. For modification, please contact your local service department. See http://support.flir.com/service for contact details.TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start/stop/general), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highOutput to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminalComposite video output, PAL and NTSC compatibleCVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)Standard BNC connector12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
- Utility CD-ROM
495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558003336845188003081Sweden
42701-1001FLIR A300 (9 Hz)320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.39 HzAutomatic or manual (built in motor)1–8× continuous, digital, interpolating zooming on imagesFocal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of readingColor palettes (BW, BW inv, Iron, Rain)Date/time, Temperature (°C/°F)Built-in memory for image storageStandard JPEG, 16-bit measurement data includedControl and image100 MbpsIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietaryMPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L516-bit 320 × 240 pixels @ 3 Hz
- Radiometric
Power over Ethernet, PoE IEEE 802.3af class 0. In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet, in some rare cases the camera will not be powered. In such cases, power the camera using the external power cable, or modify the camera according to Service bulletin SB14-006. For modification, please contact your local service department. See http://support.flir.com/service for contact details.TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start/stop/general), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highOutput to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminalComposite video output, PAL and NTSC compatibleCVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)Standard BNC connector12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
- Utility CD-ROM
495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558003343845188003098Sweden
48201-1101FLIR A310320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.330 HzAutomatic or manual (built in motor)1–8× continuous, digital, interpolating zooming on imagesFocal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of reading10 (with no image streaming)10 boxes with max./min./average/position (with no image streaming)1 with above/below/intervalMeasurement Mask Filter Schedule response: File sending (ftp), email (SMTP)Delta temperature between measurement functions or reference temperatureManually set or captured from any measurement functionAutomatic, based on inputs for distance, atmospheric temperature and relative humidityAutomatic, based on signals from internal sensorsVariable from 0.01 to 1.0Automatic, based on input of reflected temperatureAutomatic, based on input of optics/window transmission and temperatureGlobal and individual object parameters6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timerDigital Out, log, store image, file sending (ftp), email (SMTP), notificationColor palettes (BW, BW inv, Iron, Rain)Date/time, Temperature (°C/°F)Built-in memory for image storageStandard JPEG, 16-bit measurement data includedControl, result and image100 MbpsIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietaryMPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L516-bit 320 × 240 pixels @ 7-8 Hz
- Radiometric
Power over Ethernet, PoE IEEE 802.3af class 0. In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet, in some rare cases the camera will not be powered. In such cases, power the camera using the external power cable, or modify the camera according to Service bulletin SB14-006. For modification, please contact your local service department. See http://support.flir.com/service for contact details.Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start/stop/general), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highAs function of ALARM, Output to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminalComposite video output, PAL and NTSC compatibleCVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)Standard BNC connector12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
- Utility CD-ROM
2.85 kg (6.3 lb.)495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558003350845188003104Sweden
42701-1101FLIR A310 (9 Hz)320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.39 HzAutomatic or manual (built in motor)1–8× continuous, digital, interpolating zooming on imagesFocal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of reading10 (with no image streaming)10 boxes with max./min./average/position (with no image streaming)1 with above/below/intervalMeasurement Mask Filter Schedule response: File sending (ftp), email (SMTP)Delta temperature between measurement functions or reference temperatureManually set or captured from any measurement functionAutomatic, based on inputs for distance, atmospheric temperature and relative humidityAutomatic, based on signals from internal sensorsVariable from 0.01 to 1.0Automatic, based on input of reflected temperatureAutomatic, based on input of optics/window transmission and temperatureGlobal and individual object parameters6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timerDigital Out, log, store image, file sending (ftp), email (SMTP), notificationColor palettes (BW, BW inv, Iron, Rain)Date/time, Temperature (°C/°F)Built-in memory for image storageStandard JPEG, 16-bit measurement data includedControl, result and image100 MbpsIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietaryMPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L516-bit 320 × 240 pixels @ 4.5 Hz
- Radiometric
Power over Ethernet, PoE IEEE 802.3af class 0. In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet, in some rare cases the camera will not be powered. In such cases, power the camera using the external power cable, or modify the camera according to Service bulletin SB14-006. For modification, please contact your local service department. See http://support.flir.com/service for contact details.Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start/stop/general), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highAs function of ALARM, Output to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminalComposite video output, PAL and NTSC compatibleCVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)Standard BNC connector12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
- Utility CD-ROM
495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558003367845188003111Sweden
48001-1101FLIR A315320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.360 HzAutomatic or manual (built in motor)Focal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of readingAutomatic, based on inputs for distance, atmospheric temperature and relative humidityAutomatic, based on signals from internal sensorsVariable from 0.01 to 1.0Automatic, based on input of reflected temperatureAutomatic, based on input of optics/window transmission and temperatureGlobal object parametersControl and imageGigabit EthernetIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietary and GenICam protocol16-bit 320 × 240 pixels @ 60 Hz
- Signal linear
- Temperature linear
- Radiometric
TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start, stop, general), Image flow control, (stream on/off), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highOutput to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminal12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
- Utility CD-ROM
495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558003374845188003128Sweden
42901-1101FLIR A315 (9 Hz)320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.39 HzAutomatic or manual (built in motor)Focal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of readingAutomatic, based on inputs for distance, atmospheric temperature and relative humidityAutomatic, based on signals from internal sensorsVariable from 0.01 to 1.0Automatic, based on input of reflected temperatureAutomatic, based on input of optics/window transmission and temperatureGlobal object parametersControl and imageGigabit EthernetIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietary and GenICam protocol16-bit 320 × 240 pixels @ 9 Hz
- Signal linear
- Temperature linear
- Radiometric
TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start, stop, general), Image flow control, (stream on/off), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highOutput to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminal12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
- Utility CD-ROM
495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558003381845188003135Sweden
48201-1201FLIR A320 Tempscreen320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.330 HzAutomatic or manual (built in motor)1–8× continuous, digital, interpolating zooming on imagesFocal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of reading44 boxes with max./min./average/position1 with above/below/intervalMeasurement Mask Filter Schedule response: File sending (ftp), email (SMTP)Delta temperature between measurement functions or reference temperatureManually set or captured from any measurement functionAutomatic, based on inputs for distance, atmospheric temperature and relative humidityAutomatic, based on signals from internal sensorsVariable from 0.01 to 1.0Automatic, based on input of reflected temperatureAutomatic, based on input of optics/window transmission and temperatureGlobal and individual object parameters6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timerDigital Out, log, store image, file sending (ftp), email (SMTP), notificationDifference temperature alarm with dynamic updated reference temperature (visualized by the isotherm)Color palettes (BW, BW inv, Iron, Rain)Date/time, Temperature (°C/°F)Built-in memory for image storageStandard JPEG, 16-bit measurement data includedControl, result and image100 MbpsIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietaryMPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L516-bit 320 × 240 pixels
- Signal linear
- Temperature linear
- Radiometric
Power over Ethernet, PoE IEEE 802.3af class 0. In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet, in some rare cases the camera will not be powered. In such cases, power the camera using the external power cable, or modify the camera according to Service bulletin SB14-006. For modification, please contact your local service department. See http://support.flir.com/service for contact details.TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start/stop/general), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highAs function of ALARM, Output to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminalComposite video output, PAL and NTSC compatibleCVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)Standard BNC connector12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
- Utility CD-ROM
495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558003398845188003142Sweden
42701-1201FLIR A320 Tempscreen (9 Hz)320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.39 HzAutomatic or manual (built in motor)1–8× continuous, digital, interpolating zooming on imagesFocal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of reading44 boxes with max./min./average/position1 with above/below/intervalMeasurement Mask Filter Schedule response: File sending (ftp), email (SMTP)Delta temperature between measurement functions or reference temperatureManually set or captured from any measurement functionAutomatic, based on inputs for distance, atmospheric temperature and relative humidityAutomatic, based on signals from internal sensorsVariable from 0.01 to 1.0Automatic, based on input of reflected temperatureAutomatic, based on input of optics/window transmission and temperatureGlobal and individual object parameters6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timerDigital Out, log, store image, file sending (ftp), email (SMTP), notificationDifference temperature alarm with dynamic updated reference temperature (visualized by the isotherm)Color palettes (BW, BW inv, Iron, Rain)Date/time, Temperature (°C/°F)Built-in memory for image storageStandard JPEG, 16-bit measurement data includedControl, result and image100 MbpsIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietaryMPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L516-bit 320 × 240 pixels
- Signal linear
- Temperature linear
- Radiometric
Power over Ethernet, PoE IEEE 802.3af class 0. In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet, in some rare cases the camera will not be powered. In such cases, power the camera using the external power cable, or modify the camera according to Service bulletin SB14-006. For modification, please contact your local service department. See http://support.flir.com/service for contact details.TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start/stop/general), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highAs function of ALARM, Output to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminalComposite video output, PAL and NTSC compatibleCVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)Standard BNC connector12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
- Utility CD-ROM
495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558003404845188003159Sweden
48001-1001FLIR A325sc320 × 240 pixels< 0.05°C @ +30°C (+86°F) / 50 mK25° × 18.8°0.4 m (1.31 ft.)18 mm (0.7 in.)1.36 mradAutomatic1.360 HzAutomatic or manual (built in motor)Focal plane array (FPA), uncooled microbolometer7.5–13 µm25 µmTypical 12 ms- –20 to +120°C (–4 to +248°F)
- 0 to +350°C (+32 to +662°F)
±2°C (±3.6°F) or ±2% of readingAutomatic, based on inputs for distance, atmospheric temperature and relative humidityAutomatic, based on signals from internal sensorsVariable from 0.01 to 1.0Automatic, based on input of reflected temperatureAutomatic, based on input of optics/window transmission and temperatureGlobal object parametersControl and imageGigabit EthernetIEEE 802.3RJ-45TCP/IP socket-based FLIR proprietary and GenICam protocol16-bit 320 × 240 pixels @ 60 Hz
- Signal linear
- Temperature linear
- Radiometric
TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnPImage tag (start, stop, general), Image flow control, (stream on/off), Input ext. device (programmatically read)2 opto-isolated, 0–1.5 V = low, 3–25 V = highOutput to ext. device (programmatically set)2 opto-isolated, ON = supply (max. 100 mA), OFF = open500 VRMS6–24 VDC, max. 200 mA6-pole jackable screw terminal12/24 VDC, 24 W absolute max.2-pole jackable screw terminalAllowed range 10–30 VDC–15°C to +50°C (+5°F to +122°F)–40°C to +70°C (–40°F to +158°F)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)- EN 61000-6-2:2001 (Immunity)
- EN 61000-6-3:2001 (Emission)
- FCC 47 CFR Part 15 Class B (Emission)
IP 40 (IEC 60529)25 g (IEC 60068-2-27)2 g (IEC 60068-2-6)0.7 kg (1.54 lb.)170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)UNC ¼"-20 (on three sides)2 × M4 thread mounting holes (on three sides)AluminumCardboard box- Infrared camera with lens
- Ethernet cable
- Hard transport case
- Mains cable
- Power cable, pig-tailed
- Power supply
- Printed documentation
5.0 kg (11.0 lb.)495 × 370 × 192 mm (19.5 × 14.6 × 7.6 in.)7332558004203845188004231Sweden